PFM920I-6U-C-100

UTP CAT6 Cable

PFM920I-6U-C-100

UTP CAT6 Cable

> 100 m (328 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor material

> Customized PVC outer sheath; CE CPR Eca flame retardant class certi fied

> Top-notch Quality Commitment for 10 Years


DESCRIPTION

DESCRIPTION

Conductor

Material

Oxygen free copper (99.97% purity)

Diameter

0.57 mm ± 0.01 mm (0.0224″±0.0004″)

American Wire Gauge

23AWG

Insulation

Material

HDPE

Min. Average Thickness

0.21 mm (0.0083″)

Diameter

1.0 mm ± 0.1 mm (0.0394″±0.004″)

Color (4 Pairs)

Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

Separator

Material

PE

Specification

Translucent 4.5 mm × 0.4 mm (0.1772″ ± 0.0157″)

Rip Cord

Material

Polyester

Specification

500D

Sheath

Material

PVC

Min. Average Thickness

0.5 mm (0.0197″)

Diameter

6.3 mm ± 0.3 mm (0.2480″±0.0118″)

Color

White

Electrical

Max. DC Resistance of a Single Conductor

7.5Ω/100 m

Min. Insulation Resistance

5000MΩ·km

Max. DC Resistance Unbalance

2% (pair intra), 4% (pairs inter)

Dielectric Strength

No breakdown with 1kV DC for 1 min

Transmission

Characteristic Impedance

100 Ω ± 15 Ω

Near End Cross Talk

≥39.30 dB/100 m @250 MHz

Max. Attenuation

33 dB/100 m @250 MHz

Return Loss

≥17.3 dB/100 m @250 MHz

Mechanical

Tensile Strength

Sheath≥9 MPa, insulation≥16 MPa

Elongation at Break

Sheath≥100%, insulation≥100%

Installation Bending Radius

>8 times of outer cable diameter

Conductor Elongation at Break

≥8%

Environmental

Shrinkage of Insulation

≤5%

Color Migration Resistance of Insulation

No migration

Sheath Tensile Strength and Elongation at Break after Aging

≥6.3 MPa, ≥100%

Low Temperature Bending Test

No cracking after the test

Heat Shock Test

No cracking after the test

Operating Temperature

–20°C to +60°C (–4°F to 140°F)

Installation Temperature

0°C to +50°C (32°F to 122°F)

Storage Temperature and Humidity

–10°C to +40°C (14°F to 104°F), <60% (RH)

Security

Vertical Fire Propagation Test

Comply with IEC 60332-1-2

Packaging

Cable Length

100.0 m (328.08 ft) ±1 m (3.28 ft)

Inner Carton Dimensions

286 mm × 119 mm × 289 mm

(11.26″ × 4.69″ × 11.38″) (L × W × H)

Net Weight

4.2 kg ± 0.3 kg (9.26 lb±0.66 lb)

Gross Weight

4.5 kg ± 0.3 kg (9.92 lb±0.66 lb)

Packaging Dimensions

595 mm × 310 mm × 270 mm

(23.43″ × 12.20″ × 10.62″) (L × W × H)

Packaging Method

100 m/carton, 4 inner cartons in one package

Compliance

Executive Standards

ISO/IEC 11801-1-2017, IEC 61156-5-2009

Certification

Certification

CPR Eca

SUBMIT YOU Queries